530 CyberSWITCH
SSB: i960 I/O memory copy differs from flash image at <address>
After loading the i960 POST tests into the I/O memory, a value unexpectedly changed at the
address given.
SSB: i960 Memory read error at <address>, expected <value>, read <value>
While testing the shared memory area (I/O memory and the peripheral buffer memory), an error
was detected. The boot process should continue; however, make note of the error message in the
event of a future problem.
SSB: i960 POST number not equal to i386’s
The i386 requested the i960 to run a specific POST. Upon receiving the response, from the i960, it
was determined that a different POST was actually run.
The boot process should continue; however, make note of the error message in the event of a future
problem.
SSB: Post 23 i960host_int_reg FAILURE
The i960 failed its internal register test. The boot process should continue; however, make note of
the error message in the event of a future problem.
SSB: Post 24 i960io_int_reg FAILURE
The i960 failed its I/O register test. The boot process should continue; however, make note of the
error message in the event of a future problem.
SSB: Post 25 i960io_mod_mem_1 FAILURE
The i960 failed its I/O memory test using the first test pattern. The boot process should continue;
however, make note of the error message in the event of a future problem.
SSB: Post 26 i960io_mod_mem_2 FAILURE
The i960 failed its I/O memory test using the second test pattern. The boot process should continue;
however, make note of the error message in the event of a future problem.
SSB: Post 27 i960timer_82c54FAILURE
The i960 failed its timer unit test. The boot process should continue; however, make note of the
error message in the event of a future problem.
SSB: Post 28 i960lan_82596sx FAILURE
The i960 failed its LAN Coprocessor test. The boot process should continue; however, make note of
the error message in the event of a future problem.
SSB: Post 29 i960lan_82503 FAILURE
The i960 failed its LAN transceiver test. The boot process should continue; however, make note of
the error message in the event of a future problem.
SSB: Post 30 i960per_mod_mem_1 FAILURE
The i960 failed its peripheral buffer memory test using the first test pattern. The boot process
should continue; however, make note of the error message in the event of a future problem.
SSB: Post 31 i960per_mod_mem_2 FAILURE
The i960 failed its peripheral buffer memory test using the second test pattern. The boot process
should continue; however, make note of the error message in the event of a future problem.