Enterasys Networks CSX7000 Manuel d'utilisateur Page 481

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 729
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 480
Central Site Remote Access Switch 481
S
YSTEM
M
ESSAGES
Informational Messages
INFORMATIONAL MESSAGES
The system records informational messages. These are normal events that provide you with current
system status. Informational messages include the following categories of messages:
initialization messages
normal operation messages
Spanning Tree messages
INITIALIZATION MESSAGES
The system reports a variety of messages during a successful system initialization. These messages
may include: status of bridge, status of LAN ports and adapters, data link, SNMP, and TFTP
information. The following are examples of typical initialization messages:
Bridge is operating in UNRESTRICTED mode
Data link up: Slot=<slot #> Port=<port #> Ces=<comm. endpoint suffix>
[SNMP] SNMP initialized successfully
NORMAL OPERATION MESSAGES
The system normal operation messages may include information such as:
Call Restrictions have been disabled by user command
WAN Port is now in the <new state> state
SPANNING TREE MESSAGES
The Spanning Tree protocol is only supported by the Ethernet-2 interface card.
Spanning Tree protocol messages are prefaced with [STP]. During normal operation, when
Spanning Tree protocol is enabled, the system may report informational messages such as:
[STP] A new Root Bridge has been detected
[STP] LAN Port <port #> is now a Designated Port
WARNING MESSAGES
System warning messages signal events that you should investigate. These messages may be
normal during certain network conditions, or they may indicate a problem. The system should
continue to operate after posting a warning message. If the system fails to operate normally, then
report it using the problem report form included in Getting Assistance.
ERROR MESSAGES
When the system detects errors, it reports error messages. If the faulty component cannot be
identified, and an error condition persists, then report the error by using the problem report form
included in Getting Assistance.