USER’S GUIDE
178 CyberSWITCH
The following table summarizes the identifying and authenticating information used by each
remote device type to connect to the system:
SYSTEM INFORMATION
CONFIGURING SYSTEM INFORMATION
USING CFGEDIT
1. Select option (2), System Information from the System Options and Information menu. If you
need guidance to find this menu, refer to the instructions provided in the System Options
configuration section. The following screen will be displayed:
2. Select the option you wish to configure and press <RET>. Follow the onscreen instructions to
configure the option you select. These values are required only if there are remote devices on
the network that require this information for system validation.
SYSTEM INFORMATION CONFIGURATION ELEMENTS
SYSTEM NAME
The System Name is a user-defined name for the CyberSWITCH. This name is preconfigured, but
may be changed. It is from 1 to 17 ASCII characters in length. The System Name is only used if there
are remote devices on the network that require this information for system validation. This name
is passed in the name field during PAP negotiation.
Device Type Identifier Authenticator
HDLC Bridge
(MAC Layer
Bridge)
Bridge Ethernet
Address
or
Calling Line Id
Bridge Ethernet Address
Optional: Password
Optional: Calling Line Id
IP Host
(with RFC 1294
encapsulation)
IP Host Id IP Host Id
Optional: Calling Line Id
PPP Device Name CHAP Secret
or
PAP Password
Optional: Calling Line Id
System Information Menu:
1) System Name is "ralph"
2) System Password is "ralph"
3) System Secret is "ralph"
Select function from above or <RET> for previous menu: 1