S
YSTEM
M
ESSAGES
System Message Summary
[SNMP] Authentication failure, improper access rights
There are two possible causes for this message:
The SNMP Agent received a SetRequest PDU that contained a Community Name with an MIB
access level of MIB GUEST or MIB USER. The MIB access level must be MIB ADMIN to per-
form a SetRequest. The request was discarded.
The SNMP Agent received a PDU that contained a Community Name with an MIB access level
of MIB GUEST and an object Id that cannot be accessed with an MIB GUEST access level. The
request was discarded.
[SNMP] Authentication failure, unknown community name
The SNMP Agent received a request PDU whose community name is not configured in the
Community Names Table. The request was discarded.
[SNMP] SNMP initialization failure - unable to allocate necessary memory
The SNMP feature was unable to initialize because it could not obtain the necessary memory. The
SNMP feature is disabled and no SNMP request will be processed. Contact your Distributor or
Customer Support.
[SNMP] SNMP initialization failure - unable to open UDP port
The SNMP feature was unable to initialize because it could not obtain the necessary UDP port. The
SNMP feature is disabled and no SNMP request will be processed. Check the configuration, and
then contact your Distributor or Customer Support.
[SNMP] SNMP initialized successfully
The SNMP Agent has been successfully initialized and is fully operational.
[SNMP] Unable to obtain an SNMP Trap queue entry buffer
The SNMP Agent attempted to generate a TRAP PDU but was unsuccessful because it could not
obtain necessary memory. The TRAP was not sent. Contact your Distributor or Customer Support.
[SNMP] Unable to obtain an SNMP Trap queue header
The SNMP Agent attempted to generate a TRAP PDU but was unsuccessful because it could not
obtain necessary memory. The TRAP was not sent. Contact your Distributor or Customer Support.
SPID FSM got unidentifiable INFO msg - Slot=<slot #> Port=<port #> Ces=<communication endpoint
suffix>
An unexpected information message was received from the network on the indicated line. If you
are having trouble establishing calls on this line, the problem should be reported to your phone
company.
SSB: Can’t read RTC prior to i960 POSTs
The Real Time Clock became inaccessible before invoking the i960 POSTs. The RTC is used to guard
against infinite loops while waiting for the i960 to run its POST tests. The boot process should
continue; however, make note of the error message in the event of a future problem.
SSB: Couldn’t read RTC during i960 POSTs
The Real Time Clock became inaccessible during the running of the i960 POSTs. The RTC is used
to guard against infinite loops while waiting for the i960 to run its POST tests. The boot process
should continue; however, make note of the error message in the event of a future problem.