Enterasys Networks CSX7000 Manuel d'utilisateur Page 427

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 729
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 426
Central Site Remote Access Switch 427
V
ERIFYING
THE
B
ASE
S
YSTEM
IP Host Mode
3. Telnet from the client PC into the central site. For example, telnet to 100.0.0.1, port 7003. Follow
the normal user level authentication process.
4. Once again, determine if the client PC can ping the Service Server. On the Client PC, type:
ping 100.0.0.2
<return>
If the ping is successful, then multi-level security is operational.
5. If the ping is unsuccessful, try the following:
a. Ensure that the remote device can ping across the network with User Level Authentication
DISABLED.
b. Disconnect the call if it is still up.
c. Check to see if the User Level Security database and server are properly configured. Ensure
that the user ID and password are accurate.
d. If the problem is still not resolved, contact Customer Support.
IP HOST MODE
IP HOST INITIALIZED?
VERIFICATION
If you have configured the IP feature in the Host mode:
1. Determine if IP Host has been initialized by viewing the system messages. To view the
messages, enter the following command:
dr
<return>
2. Look for the following IP message among the system messages:
[IP] IP Host is initialized successfully
3. For the IP Interface that has been configured, the following interface initialization message
should be displayed among the system messages:
[IP] Network initialized successfully on ddd.ddd.ddd.ddd
Note: Other messages may also be displayed with the IP router initialization messages.
If you see these IP host initialization messages, then the IP host is operational.
4. If the system does not display the correct IP Host Initialization messages, or, instead, displays
the following message:
[IP] IP Router is initialized successfully
a. Check the configuration. Make sure that the IP feature is enabled.
b. Make sure that the operating mode is set to Host rather than Router.
IP HOST MODE OPERATIONAL?
To verify that IP Host mode feature is properly operational, a remote IP Host must be operational
and available to initiate WAN connections via a remote bridge device. Also, a local IP host must be
connected to the local LAN port on the CyberSWITCH.
Vue de la page 426
1 2 ... 422 423 424 425 426 427 428 429 430 431 432 ... 728 729

Commentaires sur ces manuels

Pas de commentaire