Enterasys Networks CSX7000 Manuel d'utilisateur Page 383

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 729
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 382
Central Site Remote Access Switch 383
C
ONFIGURING
C
ALL
C
ONTROL
CSM as a Call Control Manager
CSM AS A CALL CONTROL MANAGER
This feature allows you to use the CSM for call control management only. This feature allows you
to continue to use other authentication servers (e.g., RADIUS, ACE) yet still gain the benefits of
CSM call control management.
CONFIGURING CSM FOR CALL CONTROL
USING CFGEDIT
1. Select CSM as Call Control Manager from the Call Control Options menu.
2. The current status of the CSM Call Control Server will be displayed. Select 1 to toggle between
enabled and disabled, and ensure an enabled setting.
3. Select TCP port number if you wish to change this setting. Changes here will also appear on the
CSM Authentication menu.
4. Return to the Main Menu.
5. For authentication, if you are using the On-node Device Table or Off-node Device Level Security,
you are finished with the configuration of this feature. If you are using User Level Security, you
may wish to adjust the Authentication Time-out and/or change the Call Control Failure
banner. Continue with the following steps.
6. Select Security and then Network Login Information.
7. Select Network Login General Configuration.
8. Select Authentication Timeout. Follow on-screen instructions to adjust this value.
9. Return to the Network Login Information Menu and select Network Login Banners.
10. Select the Call Control Failure Banner. Follow on-screen instructions to adjust this banner.
Note: If you are using CSM as your authentication manager, you do not have to configure the call
control option separately. This is only necessary when you are configuring another device
for authentication, and wish to use CSM for call control only.
CONFIGURATION ELEMENTS
STATUS
Allows you to enable or disable CSM for call control management.
TCP
PORT NUMBER
The TCP port number used by CSM. Note that you can assign a user-defined port number, but that
the CSM TCP port number must be entered identically on both the CyberSWITCH and CSM.
Vue de la page 382
1 2 ... 378 379 380 381 382 383 384 385 386 387 388 ... 728 729

Commentaires sur ces manuels

Pas de commentaire