Central Site Remote Access Switch 519
S
YSTEM
M
ESSAGES
System Message Summary
Missing BEARER_CAPABILITY in HOST_CALL_REQUEST
Missing CALLED_NUMBER_IE in HOST_CALL_REQUEST
Missing CHANNEL in HOST_CALL_REQUEST
Missing CHANNEL_ID_IE in HOST_CALL_REQUEST
Missing TN in HOST_CALL_REQUEST
An error has been detected in the R2 or RBS signaling procedure, and will typically result in a failed
call. The error was due to unrecognizable or incorrect information. Check configuration; if
problem persists, contact your Distributor or Customer Support.
MODEM <modem #> of DM card in slot <slot #> is unusable
An attempt was made to perform an operation on a specific modem that had been deleted from the
usable list via the modem delete command. Use the
modem add
command to make the modem
usable again, or use a different modem to perform the desired operation.
MODEM CONNECT failed - connect <connect id #>, board <board #>, modem <modem #>
An attempted modem call has failed to connect. Try reconnecting the call again. If this message
consistently appears for the same modem number, contact your distributor or Customer Support.
Modem revision on modem <modem #> of slot <slot #> failed
Individual modems on a Digital Modem card are failing. Check the hardware and software
configurations, as well as the seating of the card and the MVIP cabling. If all seems in order, contact
your Distributor or Customer Support.
Modem version comparison failed in slot <slot #> due to inconsistent format
This message displays if any of the following files are corrupted: DM56MDM.MOT,
DM56PPCU.MOT, DM24MDMU.MOT, DM24PPCU.MOT. Contact your Distributor or Customer
Support.
Negotiation Failure with Semipermanent device “x
There was some problem negotiating a connection with device "x." There was no way to send data.
This could be an authentication failure or a PPP failure.
Network loop between site1 and site 2
The system detected a WAN loop between the specified sites, so the System will not forward the
duplicate frame. Check the System and network configuration for this loop and adjust.
Network requested init but no SPID configured- Slot=<slot #> Port=<port #> Ces=<communication
endpoint suffix>
A SPID is required but is not configured on the indicated line. The configuration of the
CyberSWITCH or of the switch should be corrected.
Network sent bad Endpoint identifier - Slot=<slot #> Port=<port #> Ces=<communication endpoint
suffix>
During terminal initialization, a bad endpoint identifier was received on the indicated line. This
message is informational only; your line should continue to operate normally.
Network sent CAUSE - invalid SPID - Slot=<slot #> Port=<port #> Ces=<communication endpoint
suffix>
An invalid SPID is configured on the indicated line. The configuration of the CyberSWITCH or of
the switch should be corrected.