Console Port Pinout Assignments
A-10 Specifications
ThespecificationslistedinTable A23meetorexceedtheIEEE802.3ae2002standard.
Console Port Pinout Assignments
ReferbacktoConnectingtotheRJ45ConsolePortonpage 213forconsoleportpinout
information.
Regulatory Compliance
TheG3G12424,G3G12424PandG3G17024meetthesafetyandelectromagneticcompatibility
(EMC)requirementslistedinTable A24:
Table A-22 XFP Fiber-Optic Specifications
Module Wavelength
Tx Power
Min/Max (avg.)
Rx Sensitivity
Min/Max (avg.)
Link Power
Budget
MTBF
(hours)
10GBASE-LR-XFP 1310 nm DFB -8.2 / 0.5 dBm -14.4 / 0.5 dBm 9.4 dB 2,631,579
10GBASE-ER-XFP 1550 nm EML -4.7 / 4.0 dBm -15.8 / -1.0 dBm 15 dB 2,000,000
10GBASE-ZR-XFP 1550 nm EML 0 / 4.0 dBm -25 / -7.0 dBm 18 dB 1,164,047
10GBASE-SR-XFP 850 nm VCSEL -7.3 / -1.0 dBm -9.9 / -1.0 dBm 7.3 dB 4,081,633
Table A-23 Recommended Cable Types and Specifications
Item Type Max. Reach
Min. Reach
1
1. The limiting factor is saturation of the receiver by the transmitter. When presented with a signal at a strength
above the saturation point, the receiver cannot distinguish between pulses, though no hardware damage
occurs.
Connector
10GBASE-LR-XFP SMF (Single Mode Fiber) 10 km (6.21 mi) 2 m (6.6 ft) LC
10GBASE-ER-XFP SMF (Single Mode Fiber) 40 km (24.85 mi)
2
2. Links longer than 30 km for the same link power budget are considered engineered links. Attenuation for such
links needs to be less than the minimum
2 m (6.6 ft) with
minimum of 5 dB
attenuation
LC
10GBASE-ZR-XFP SMF (Single Mode Fiber) 80 km (49.7 mi) 2 m (6.6 ft) with
minimum of 11 dB
attenuation
LC
10GBASE-SR-XFP MMF (Multimode Fiber) 300 m (984 ft) 2 m (6.6 ft) LC
Table A-24 Compliance Standards
Regulatory Compliance Standards
Safety
UL 60950, CSA C22.2 No. 60950, 2006/95/EC, EN 60950, and
IEC 60950. The Mini-GBICs that support laser connections also
meet the EN 60825 and 21 CFR 1040.10 standards.
Electromagnetic Compatibility (EMC)
47 CFR Parts 2 and 15, CSA C108.8, 2004/108/EC, EN 55022,
EN 61000-3-2, EN 61000-3-3, EN 55024,
AS/NZS CISPR 22, and VCCI V-3.