Vue de la page 27
BRIM-E6 USER’S GUIDE Page 23
CHAPTER 4
USING THE LANVIEW LEDS
This chapter describes how to use the LANVIEW Diagnostic LEDs to
monitor BRIM status and diagnose BRIM problems.
Figure 4-1. LANVIEW LEDS
4.1 STB (Standby)
On - The bridge port is in the non-forwarding state. Possible causes
of this condition are: redundancy detected by Spanning Tree, data
link layer down, physical layer down, or port disabled.
Off - The bridge port is in the forwarding state.
4.2 XMT (Transmit)
On - The BRIM is transmitting packets.
Off - No activity.
4.3 CLN (Collision)
On - A collision has occurred on the BRIM port.
Off - No activity.
4.4 RCV (Receive)
On - The BRIM port is receiving packets.
Off - No activity.