Enterasys-networks 6H308-24 Manuel d'utilisateur Page 38

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 37
Using LANVIEW
4-2 Troubleshooting
Table 4-1 describes the LED indications and provides recommended actions as appropriate.
NOTE: The terms flashing, blinking, and solid used in Ta bl e 4- 1 indicate the following:
Flashing indicates an LED is flashing randomly.
Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50% off).
Solid indicates a steady LED light. No pulsing.
Table 4-1 LANVIEW LEDs
LED Color State Recommended Action
CPU Off Power off. Ensure chassis has adequate power.
Red Blinking. Hardware
failure has occurred.
Contact Enterasys Networks for technical
support.
Solid. Resetting, normal
power up reset.
If the LED remains red for several minutes,
contact Enterasys Networks for technical
support.
Amber Blinking. Crippled. Contact Enterasys Networks for technical
support.
Solid. Testing. If the LED remains amber for more than
several minutes, contact Enterasys
Networks for technical support.
Green Solid. Functional. None.
Amber
and
Green
Booting. Blinks amber
and green while booting.
None.