Enterasys-networks 1G58x-09 Manuel d'utilisateur Page 792

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 808
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 791
Security Configuration Command Set
Configuring Flow Setup Throttling (FST)
14-110 Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
14.3.9.6 set flowlimit shutdown
Use this command to enable or disable the flow limit shut down function. When enabled, this allows
ports configured with a “disable” action to shut down. For information on using the set flowlimit
limit command to configure set a disable action on a port, refer to Section 14.3.9.3.
set flowlimit shutdown {enable | disable}
Syntax Description
Command Type
Switch command.
Command Mode
Read-Write.
Command Defaults
None.
Example
This example shows how to enable the flow limit shut down function:
enable | disable Enables or disables the flow limit shut down function.
Matrix>set flowlimit shutdown enable