Enterasys Networks CSX7000 Manuel d'utilisateur Page 581

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 729
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 580
Central Site Remote Access Switch 581
S
YSTEM
C
OMMANDS
Viewing Operational Information
TRYING
The system is attempting to call the device. Some connections may be up, but not at the initial
data rate.
status
Displays initialization, current status, and connection information, as well as any errors that
have been detected. For details on these messages, refer to the section titled LCD Message
Groups found in the LCD Messages chapter.
time
Displays the current system time. This can be useful when viewing system messages or
statistics.
ver
Displays the version number of the software that is currently running on the system (II, III,
etc.). In addition, it displays all other custom information for this copy of the system software,
such as the platform, the installed resources, and the hardware resource revision information.
Note that T1_E1_PRI-1 indicates the PRI-23/30 adapter.
The ver command also displays a connections table. It displays the connection lines for features
that are loaded only. Consider the following example of a connections table:
Capacities
Potential Actual
Physical Connections 8 8
X.25 Connections 32 32
Frame Relay Connections
48 33
Combined Maximum Connections 88 33
Description:
The first column is the connection type.
The second column is the potential number of connections.
The third column is the actual number of connections possible. The actual number may differ
from the potential number due to memory constraints.
•The combined maximum line shows the maximum number of connections possible for all
types combined. If the potential and actual column do not match on this line, then there are
not enough connections for all the connection types to use their respective maximum num-
ber of connections at the same time.
For our example, the most connections possible without memory limitations is 88. This is the
sum of all the connection types. Since there is not enough memory for 88, the actual number of
connections available is less than that amount (33). This means that any of the following
combinations of connections would be allowed:
Physical Connections X.25 Frame Relay
8 25 0
0 32 1
0 0 33
2 2 29
Vue de la page 580
1 2 ... 576 577 578 579 580 581 582 583 584 585 586 ... 728 729

Commentaires sur ces manuels

Pas de commentaire