Enterasys Networks CSX7000 Manuel d'utilisateur Page 532

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 729
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 531
USER’S GUIDE
532 CyberSWITCH
Successfully Loaded Release <X.Y> Issue <Z>
The specified release of System software was successfully loaded into memory.
Switch could not recognize phone number nnnnnnn
The switch did not accept the phone number dialed as a complete number. Check the correctness
of the phone number (including any leading digits such as 8 or 9).
System Clock Fault on Wan Adapter in Slot <slot #>
Indicates a TDM bus connection failure. Check to make sure that the TDM bus has been correctly
connected.
TACACS authentication is not available. You must first ENABLE TACACS user level authentication.
An attempt was made to configure the Terminal Server Security for TACACS and TACACS was
not configured on the CyberSWITCH.
TCP Connection to CSM at <IP address> is DOWN; reason: <reason code>.
The TCP connection to the Connection Services Manager (CSM) has gone down. Contact your
Distributor or Customer Support and provide them with the indicated reason code.
TCP Connection to CSM at <IP address> is UP.
A TCP connection exists between this device and the CSM at the indicated IP address.
TCP Connection to CSM Lost.
The TCP connection to the CSM has gone down.
TDM Clock Master changed TO (slot #, port#) FROM (slot #, port #)
The Clock Manager has dynamically adjusted the master clock source in response to an external
line state change.
Temporarily unable to read flash file system due to flash reclaim in progress - try again later
The system is automatically performing a flash reclaim to reclaim space previously occupied by
deleted files. Wait several seconds (up to a minute maximum) and try your file system command
again.
Terminal Server Security connections disabled. Dropping call.
The Terminal Server Security is set to none and a terminal connection was requested. Check
configuration. Most likely, the Default Async Protocol is set to terminal with no Terminal Server
Security configured.
Terminal Server Security is currently using this database. You must change the Terminal Server Security
setting first.
An attempt was made to disable a User Level Security Database when the terminal server was
configured to use this database for terminal mode authentication.
[TFTP] Data buffer allocated successfully
All parts of the TFTP feature (both Server and Client) were successfully initialized.
Note: The following “[TFTP] Local error...” messages generated during client operations will be
displayed on the console only and will not be logged to disk.