Central Site Remote Access Switch 527
S
YSTEM
M
ESSAGES
System Message Summary
Security Rejection - Bridge Address Security cannot use Authentication Server
Both options (Bridge Address Security and off-node User Authentication) are not supported
simultaneously.
Security Rejection - Caller did not negotiate security
Bridge Security is configured. A caller attempted to send device data before (or without)
negotiating the Bridge Address security.
Security Rejection - HDLC not supported by the caller
A properly formed Bridge Security negotiation packet was received but the remote bridge
indicated that it did not support the HDLC protocol.
Security Rejection - Invalid Calling Line Id - <CLID>
The calling line identifier has not been configured for any valid device in the system Device list. The
number <CLID> indicates the actual number presented by the network.
Security Rejection - Invalid Password (<password>) given
A properly formed Bridge Security negotiation packet was received. The bridge is registered in the
System Device table and a password was provided, but the password provided did not match the
password in the System Device table.
Security Rejection - No Bridge Address given by caller
A normal Bridge Security negotiation packet was received, but did not contain a bridge address.
Check configuration. If problem persists, contact your Distributor or Customer Support.
Security Rejection - No Password given by caller
A properly formed Bridge Security negotiation packet was received, and the bridge is registered in
the system Device Table, but a password is required and none was provided by the calling bridge.
Check configuration. If problem persists, contact your Distributor or Customer Support.
Security Rejection - No Protocol List supplied
A Combinet has attempted to connect to the system without the required Protocol List information.
Check configuration, and then reboot the Combinet. If problem persists, contact your Distributor
or Customer Support.
Security Rejection - Timeout on Startup Complete
After a normal Bridge Security negotiation packet is received, and the System sends a response
message, there is a five second time limit in which a “Startup Complete” message must be received.
The above security rejection message is seen if the Startup Complete message is not received before
the timer expires. Check to see if the response message was received by the calling bridge.
Security Rejection - Unknown Calling Bridge - <bridge address>
A properly formed Bridge Security negotiation packet was received but the bridge address is not
registered in the system Device Table.
SemiPermanent. Local authentication failure of Semipermanent device "x"
The system failed to authenticate the indicated device. The semipermanent connection will be
disabled. Compare the authentication device information configured on the system with the actual
configuration of the remote device. Make corrections as needed. Then, issue the
call device
<device name>
command to reinstate the semipermanent connection.