System Message Summary
not be working properly. Check the configuration of the remote device and reboot. If the problem
recurs, contact your Distributor or Customer Support.
[PAP] Remote device rejected System Information <error message>
The system received the PAP Authenticate-Nak packet with the error message <error message>
against the previous PAP Authenticate-Request sent by the system. The <error message> is from
the remote device, and is device-specific. Contact the remote site for assistance.
[PAP] Unknown name <name> given by remote device
The system received the PAP Authenticate-Request packet with the unknown device name
<name>.
Post <number>, HDLC #<number> External Loopback Test FAILED
The indicated HDLC controller, 80532 Device, failed an internal register test. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number>, HDLC #<number> Internal Loopback Test FAILED
The indicated HDLC controller, 80532 Device, failed an internal loopback test. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number>, HDLC #<number> Interrupt Test FAILED
The indicated HDLC controller, 80532 Device, failed an internal interrupt test. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number>, HDLC #<number> Register Test FAILED
The indicated HDLC controller, 80532 Device, failed an internal register test. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number>, HDLC #<number> Test FAILED
The indicated HDLC controller, 80532 Device, failed one of the constituent POSTs. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number>, ISDN Test FAILED
The specified D-channel controller, one of 4 2086 devices, did not pass its POST. The boot process
should continue; however, make note of the error message in the event of a future problem.
Post <number> memory read error at <address>, expected <value>, read <value>
The specified memory POST failed at the specified address, with both the expected and actual
memory values displayed. The boot process should continue; however, make note of the error
message in the event of a future problem.
Post <number> NVRAM Failure
The non-volatile RAM failed during its POST. The boot process should continue; however, make
note of the error message in the event of a future problem.
Post <number>, timed out waiting for i960 to respond during POSTs
The i960 failed to respond during the allotted amount of time during the specified POST. This is an
i960 failure. The boot process should continue; however, make note of the error message in the
event of a future problem.
[PPP] Link Failure Detected: No response to periodic Echo-Requests.
This message is logged by the feature when it detects a failed link.