Enterasys Networks CSX7000 Manuel d'utilisateur Page 503

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 729
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 502
Central Site Remote Access Switch 503
S
YSTEM
M
ESSAGES
System Message Summary
Facility not subscribed - Slot=<slot #> Port=<port #>
This probably indicates a SPID configuration error on the indicated line. The configuration should
be corrected on the system or the switch.
Failed to allocate enough memory for XILINX load file
The WAN card initialization subsystem failed to allocate a buffer for use in downloading files.
Restart the system. If the problem continues, contact your Distributor or Customer Support.
FAILED TO BOOT SYSTEM SOFTWARE
While attempting to load the System software, an error was detected. The system will automatically
reset and attempt a reboot in an effort to correct the problem. If the system continues to fail, make
note of the displayed messages, and contact your Distributor or Customer Support. A software
update is likely needed.
FAILED TO FORMAT RFA
The Flash File System could not be formatted. The system will automatically reset and attempt a
reboot in an effort to correct the problem. If the system continues to fail, make note of the displayed
messages, and contact your Distributor or Customer Support. A software update is likely needed.
Failed to get a tone signaling session
An error has been detected in the R2 signaling procedure, and will typically result in a failed call.
The error was due to unrecognizable or incorrect information. If problem persists, contact your
Distributor or Customer Support.
FAILED TO INSTALL XMODEM FILESET INTO FLASH MEMORY
While writing a file into the Flash File System, an error was detected. The system will automatically
reset and attempt a reboot in an effort to correct the problem. If the system continues to fail, make
note of the displayed messages, and contact your Distributor or Customer Support. A software
update is likely needed.
Failed to obtain Terminal info in smgr_proc_terminal_auth_sess 0
A session control block was not found for this authentication session. Contact your Distributor or
Customer Support.
Failed to start a Terminal Auth session. Device + User level Security not enabled
A terminal mode connection was received and Device + User level security was not enabled. Verify
correct security settings and default async protocol settings.
FAILED XMODEM INITIALIZATION
The UART controlling the Console Information Port (CIP) could not be initialized. The system will
automatically reset and attempt a reboot in an effort to correct the problem. If the system continues
to fail, make note of the displayed messages, and contact your Distributor or Customer Support. A
software update is likely needed.
FAILED XMODEM SESSION
The X-Modem session did not successfully terminate. Likely causes include exhausting timeout
limits and noisy lines. The system will automatically reset and attempt a reboot in an effort to
correct the problem. If the system continues to fail, make note of the displayed messages, and
contact your Distributor or Customer Support. A software update is likely needed.
Vue de la page 502
1 2 ... 498 499 500 501 502 503 504 505 506 507 508 ... 728 729

Commentaires sur ces manuels

Pas de commentaire