Enterasys Networks CSX7000 Manuel d'utilisateur Page 375

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 729
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 374
Central Site Remote Access Switch 375
C
ONFIGURING
C
ALL
C
ONTROL
Call Restrictions
Two actions are available if this limit is exceeded. These actions are:
1. The call will not be allowed; a message will be displayed on the LCD, and written to the report
log.
2. The call will be allowed; however, a warning will be displayed on the LCD, and written to the
report log.
Note: Existing calls will not be disconnected when this limit is reached. Subsequent calls may not
be allowed, but existing calls will be allowed to continue.
M
AXIMUM CALL MINUTES PER MONTH
The maximum number of call minutes per month. The default value is 5520 call minutes per month.
Call minutes will be calculated periodically while calls are active (not when a call is disconnected).
Statistics will be kept to track the total number of call minutes made per month. This statistic will
be written to the statistics log every half hour, and available through the
ds
command. The current
value of this statistic will be displayed on the LCD, and will also be displayed on the monitor when
the
cr stats
command is used.
Two actions are available if this limit is exceeded. These actions are:
1. The call will not be allowed; a message will displayed on the LCD, and be written to the report
log.
2. The call will be allowed; however, a warning will be displayed on the LCD, and written to the
report log.
Note: Existing calls will not be disconnected when this limit is reached. Subsequent calls may not
be allowed, but existing calls will be allowed to continue.
M
AXIMUM CALL LENGTH
The maximum amount of time (in minutes) that a call is allowed to be active. The default value is
240 minutes.
Note: The system checks for violation of configured maximum call length every five minutes. So,
for example, if you set the maximum call length to one minute, there will be a five minute
window around that one minute in which the system will check for a violation.
Two actions are available if a call exceeds this limit. These actions are:
1. The call is disconnected; a message will be displayed on the LCD, and written to the report log.
2. The call is continued; however, a warning will be displayed on the LCD, and written to the
report log.
A
UDIBLE ALARM STATUS
The audible alarm can be enabled or disabled. This alarm is used to signal you when a call
restriction has been violated. The alarm is a series of beeps, that are repeated every 5 minutes while
any call restriction is in violation.
Vue de la page 374
1 2 ... 370 371 372 373 374 375 376 377 378 379 380 ... 728 729

Commentaires sur ces manuels

Pas de commentaire