Troubleshooting Checklist
Troubleshooting 4-7
User parameters
(IP address,
Device and
Module name,
etc.) were lost
when the
2H258-17R
power was cycled
or the front panel
RESET button
was pressed.
1. Position of Mode switch
(7), NVRAM Reset, was
changed sometime before
either cycling power or
pressing the RESET
button, causing the
user-entered parameters to
reset to factory default
settings.
2. Clear NVRAM was set
through Local
Management.
1. Reenter the lost parameters as necessary.
Refer to SmartSwitch Series 2E253,
2H252, 2H253, and 2H258 Local
Management User’s Guide for the
instructions to configure the device
through Local Management.
2. If the problem continues, contact Enterasys
Networks for assistance.
Table 4-2 Troubleshooting Checklist (Continued)
Problem Possible Cause Recommended Action