Installing the Device
Installation 3-7
Figure 3-4 Installing the Device in a Rack
3.3.3 Connecting Power
To connect the 2H258-17R to the power sources, proceed as follows:
1. Plug each power cord into a grounded wall outlet, see Figure 3-5. To take advantage of the load
sharing and redundancy capabilities, each power cord must be plugged into a separate dedicated
ac outlet. The POWER (PWR) LED turns ON (green) and the CPU LED alternates between
green and amber during boot up. It takes approximately one minute for the 2H258-17R to boot
up.
NOTE: The two power supplies in the 2H258-17R have automatic voltage sensing that
allows connection to power sources ranging from 100–125 Vac, 2.5 A or 200–240 Vac,
1.25 A, 50/60 Hz.
NOTE: If the power-up sequence is interrupted on this device, or if optional hardware
has been installed or removed, this device may run an extended diagnostics sequence
that may take up to five minutes to complete.
Screws
19-Inch Rack
3068-05
2H258-17R
COM
PWR
CPU
RESET
RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX
123456 8910 151611 12 14137
FAST ETHERNET WORKGROUP SWITCH