Installing Optional XFPs
3-4 Hardware Installation
Installing the XFP
ToinstallanXFPthathasanLCconnector,refertoFigure 31,andproceedasfollows:
1. HoldtheXFPwiththetopsidepositionedasshown,andtheedgeconnectorfacing
theportslot.
2. AligntheXFPwiththeportslot.
3. PushtheXFPintotheportslotuntiltheXFP
“clicks”andlocksintoplace.
Figure 3-1 XFP with LC Connector
Removing the XFP
1 XFP 4 Port slot
2 XFP,
top side 5 Protective dust cover
3 Edge connector (insertion side) 6 Wire handle (for XFP release)
C
2K122-24
25
26
25
26
T
X
R
X
Ä
Á
À
Â
Ã
Å
Caution: Do NOT remove the XFP from the port slot without releasing it. The XFP is
released by pulling down on its wire handle. Attempting to remove the XFP without
releasing it can damage the XFP.
The XFP and its host switch are sensitive to static discharges. Use an antistatic wrist strap
and observe all static precautions during this procedure. Failure to do so could result in
damaging the XFP or host switch. Always leave the XFP in the antistatic bag or an
equivalent antistatic container when not installed.
Precaución: NO quite el XFP de la ranura sin antes abrir la traba ubicada en la parte
frontal del XFP. Si lo hace, puede dañar el XFP, puesto que es muy sensible a las
descargas de electricidad estática, al igual que el dispositivo host. Utilice la pulsera
antiestática y tome todas las precauciones necesarias durante este procedimiento. Si no
lo hace, pude dañar el XFP o el dispositivo host. Mientras no esté instalado, mantenga el
XFP en su bolsa antiestática o en cualquier otro recipiente antiestático.